Mist Eliminators for Marine Scrubbers: EGCS Compliance

How Does a Wire Mesh Demister Work? A Complete Guide
10/30/2026
Coalescer Internals for Alkylation Unit Acid Settlers: Wire Mesh, Corrugated Plates and Distribution Plates
10/30/2026
How Does a Wire Mesh Demister Work? A Complete Guide
10/30/2026
Coalescer Internals for Alkylation Unit Acid Settlers: Wire Mesh, Corrugated Plates and Distribution Plates
10/30/2026

Understanding EGCS and the Role of Mist Eliminators

Mist Eliminators For Marine Scrubbers: Egcs Compliance. Exhaust Gas Cleaning Systems (EGCS), commonly known as scrubbers, are essential for marine vessels to comply with sulfur emission regulations. These systems use seawater or freshwater to wash exhaust gases, removing sulfur oxides (SOx) and particulate matter. A critical component of any scrubber is the mist eliminator, which prevents liquid carryover into the atmosphere and protects downstream equipment. Without effective gas-liquid separation, scrubbers risk non-compliance and operational issues.

Mist eliminators, such as wire mesh demisters and vane packs, capture fine droplets entrained in the exhaust gas. The choice of technology depends on droplet size, flow rate, and system design. This guide explores how mist eliminators contribute to EGCS compliance and what engineers should consider for optimal performance.

Key Mist Eliminator Technologies for Marine Scrubbers

Marine scrubbers demand robust, corrosion-resistant mist eliminators that handle high gas velocities and varying loads. Three primary technologies are used:

  • Wire Mesh Demisters: Constructed from woven metal or plastic mesh, these demisters provide high-efficiency capture of fine droplets (down to 10 microns) through inertial impaction and coalescence. They are compact, cost-effective, and suitable for most scrubber designs.
  • Vane Packs: Also known as chevron separators, vane packs use a series of angled blades to direct gas flow, causing droplets to impact and drain. They handle higher liquid loads and are less prone to fouling than mesh, making them ideal for scrubbers with high particulate content.
  • Coalescers: Fiberbed coalescers use fine fibers to capture submicron droplets, which merge into larger drops and drain away. They are often used as a final polishing stage to achieve ultra-low emissions.

Each technology has trade-offs in efficiency, pressure drop, and maintenance. A combination of vane packs and wire mesh demisters is common in marine scrubbers to balance performance and reliability.

Ensuring Compliance: Design and Operational Considerations

EGCS compliance requires mist eliminators to consistently achieve low droplet carryover, typically measured as a percentage of scrubber water flow. Regulations such as IMO 2020 and regional sulfur caps mandate strict emission limits. To meet these, engineers must consider:

  • Droplet Size Distribution: Scrubber exhaust contains droplets ranging from submicron to over 100 microns. Mist eliminators must be selected to capture the target size range efficiently.
  • Gas Velocity: Higher velocities increase capture efficiency but also pressure drop. Wire mesh demisters typically operate at 3-6 m/s, while vane packs can handle up to 10 m/s.
  • Corrosion and Fouling: Seawater scrubbers are prone to scaling and corrosion. Materials like duplex stainless steel or high-performance plastics are essential for longevity.
  • Maintenance Access: Regular inspection and cleaning are critical. Design should allow easy removal of mist eliminator elements without extensive downtime.

Operators should also monitor pressure drop across the mist eliminator as an indicator of fouling. A sudden increase may signal blockage, requiring cleaning or replacement.

Integration with Oil-Water Separation Systems

Scrubber washwater contains pollutants, including polycyclic aromatic hydrocarbons (PAHs) and heavy metals, which must be removed before discharge. Oil-water separators are employed to treat washwater, and mist eliminators play a role in protecting these systems. Carryover from the scrubber can overload the oil-water separator, reducing its efficiency. By minimizing liquid carryover, mist eliminators help maintain the performance of coalescers and separators downstream.

In closed-loop scrubbers, where washwater is recirculated, effective gas-liquid separation is even more critical. Mist eliminators prevent droplets from entering the exhaust stack and ensure that the recirculated water remains within acceptable quality limits.

Case Study: Optimizing Scrubber Performance with Advanced Internals

A recent retrofit on a large container vessel illustrates the importance of proper mist eliminator selection. The original scrubber used a basic wire mesh demister, but frequent fouling and high carryover led to non-compliance with sulfur emission limits. Engineers replaced the demister with a hybrid vane pack and high-efficiency coalescer, resulting in a 90% reduction in droplet carryover and a pressure drop decrease of 20%. The system now consistently meets IMO 2020 requirements, and maintenance intervals have been extended from monthly to quarterly.

This case highlights how advanced gas-liquid separation technologies can enhance reliability and compliance. It also underscores the need for collaboration between scrubber OEMs and mist eliminator manufacturers to tailor solutions to specific operating conditions.

Conclusion: Selecting the Right Mist Eliminator for EGCS Compliance

Mist eliminators are vital for marine scrubbers to achieve and maintain EGCS compliance. By understanding the available technologies and their trade-offs, engineers can make informed decisions that balance efficiency, pressure drop, and maintenance. Regular monitoring and maintenance are equally important to ensure long-term performance.

As a manufacturer of mist eliminators, wire mesh demisters, vane packs, coalescers, and separator internals, Influent Separation supports the marine industry with engineered solutions for gas-liquid separation. Our products are designed to meet the rigorous demands of scrubber systems, helping vessels comply with environmental regulations while minimizing operational costs. For more information on selecting the right internals for your EGCS, consult with our technical team.

Related Products and Resources

Related Products and Resources

Frequently Asked Questions

Which mist eliminator arrangement meets a 0.10% sulphur limit in an open loop scrubber?

Typically a two stage arrangement: a vane or louvre stage for bulk droplet removal followed by a finer mesh stage, with washwater distributed above each stage. A single stage is adequate for bulk carryover but usually cannot hold the outlet droplet loading that the sulphur compliance margin requires.

Why does washwater quality matter if the eliminator only removes droplets?

Because the droplets it fails to remove are washwater, and that washwater carries the sulphur and particulates the scrubber has just captured. Carryover is therefore a compliance issue as well as a plume issue: alkali or particulate leaving with the gas is measured as an emission even though it was removed from the gas earlier.

What is the most common cause of a rising pressure drop at sea?

Soot from incomplete combustion and sulphate deposits from the washwater, both of which narrow the passage. The practical countermeasures are full-face wash coverage rather than spot washing, generous passage dimensions, and trending pressure drop against corrected gas flow so fouling is detected before carryover appears.

How should material be chosen for washwater at 50 to 80 degrees C?

Super duplex, 6Mo or nickel alloy for metallic parts, and PP or PVDF where temperature allows, particularly in the low temperature section downstream of the wash. SS316L is generally not adequate in chlorinated seawater at these temperatures because pitting and crevice attack begin early and progress fast.

What does a plume after the funnel tell you about the eliminator?

That liquid is leaving with the gas in a quantity the eliminator should have removed, which usually means flooding, a bypass path at the shell, or washwater being injected where it cannot drain back. Plume alone does not distinguish between them: pressure drop, washwater flow and a velocity traverse across the face do.