10/30/2026Short answer: a wire mesh demister works by making the gas turn many times around fine wires. Droplets above about 10 microns cannot follow those turns, hit the wires and coalesce; the merged liquid drains to the bottom of the pad while clean gas passes. Nothing filters the droplets — they are removed by momentum and then by gravity.
The three capture mechanisms
| Mechanism | Droplet size where it dominates | What is happening |
|---|---|---|
| Inertial impaction | above roughly 10 microns | The droplet’s momentum carries it across the gas streamline and onto the wire |
| Interception | about 1 to 10 microns | The droplet follows the streamline but its radius brings it into contact with the wire |
| Diffusion | below about 1 micron | Brownian motion moves very small particles across streamlines; contribution is small in a mesh pad |
Impaction dominates in the range that matters for most industrial separators. That is why the practical cut of a knitted pad sits around 10 microns and why a coarser mesh cuts at a larger size.
Efficiency as a function of droplet size
The relationship is not linear. Efficiency is high and roughly flat above the cut size, then falls away sharply below it. In practical terms:
| Droplet size | Typical behaviour of a standard knitted pad |
|---|---|
| Above 30 microns | Very high capture; the pad is limited by liquid load, not efficiency |
| 10 to 30 microns | High capture, the main working range |
| 3 to 10 microns | Partial capture; efficiency falls with decreasing size |
| Below about 3 microns | Poor capture; a fiberbed element or another technology is needed |
From capture to drainage
Captured liquid does not leave immediately. It builds on the wires, coalesces into films and droplets at contact points, and then drains downward under gravity. Three things can interrupt that path:
- Excess liquid load: liquid accumulates faster than it drains, the pad floods, and carryover rises.
- Excess velocity: the gas shears liquid off the wires before it reaches the bottom, which is re-entrainment.
- Poor wall contact: gas finds a path around the pad edge and bypasses the mesh entirely, so nothing is captured there.
All three show up as carryover, which is why diagnosing a demister problem requires pressure drop and liquid load data, not just an outlet mist reading. The diagnostic sequence is set out in Demister Flooding and Re-entrainment.
Pressure drop: where it comes from
Pressure drop has a dry component, from flow through the wire matrix, and a wet component, from the liquid film held on the wires. The dry value is stable and predictable; the wet value rises as liquid retention increases. This is why a pad can show normal pressure drop while still carrying liquid over: the flooding has not yet developed enough to move the gauge. Expected values by internal type are compared in What Pressure Drop Should You Expect from a Mist Eliminator.
Turndown and part-load behaviour
At low gas velocity the pad still captures, but the pressure drop signal becomes small and therefore hard to trend, and liquid may not be carried to the pad at all if upstream conditions change. At high velocity, efficiency rises until re-entrainment begins, then falls quickly. The usable band is narrower than the mechanical limits of the pad suggest.
Why the same pad performs differently in two plants
Identical pads behave differently because performance depends on the approach flow, the liquid load and the drainage arrangement, not on the mesh alone. A pad in a vessel with a poorly distributed inlet sees a local velocity far above the average, and that zone carries liquid through while the rest of the pad looks fine. That is why flow distribution upstream is part of the demister design, not a separate topic — see Calming Baffles and Perforated Plates.
Pad construction parameters are covered in Design of a Wire Mesh Demister, and area sizing in How to Size a Demister.
Send the gas flow, operating pressure and temperature, expected droplet size distribution, liquid load and vessel arrangement and we will state what capture the pad can achieve and where the limits are.
Frequently Asked Questions
How does a wire mesh demister actually capture droplets?
Why does efficiency drop for very small droplets?
Where does the pressure drop come from?
What happens if the gas velocity is too high?
- Gas-Liquid Separation Fundamentals — terminology, separation mechanisms and internal selection
- Technical Data Sheet — material and performance reference data
- All Technical Articles — complete engineering index
If you are working on a replacement
A wire mesh pad performs only if it seals to the shell all round, so the measured inside diameter matters as much as the mesh density. See the process data needed to size and select it, what can and cannot be compressed on an urgent replacement and the scope from data review through to delivery.
More on wire mesh demisters and demister pads
- Demister Sizing: Why Western and Chinese Conventions Give Different Diameters
- Why the Same Demister Duty Gives Different Diameters: Five Conventions That Move the Answer
- Reboiler Mist Eliminators in Ethylene, C3 Splitter Heat Pumps and Refrigeration Chillers
- Why a Shorter Kettle Bundle Can Need a Larger Shell: Length, Diameter and Which Area Binds
- Entrainment Prediction in Kettle Reboilers, Why the Element Is Not Free to Size, and What CFD Is Actually For
Not sure which technology fits the duty at all? Which Mist Eliminator or Coalescer Do You Need? A Selection Map by Duty compares all four on droplet cut point, pressure drop and fouling tolerance.