Demister Flooding and Re-entrainment: Causes, Diagnosis and Fixes
11/09/2026Mist Eliminator Material Selection: SS316L, Duplex, Hastelloy or PTFE?
11/09/2026A mist eliminator datasheet is only useful if it states six things: maximum vapor flow, operating pressure and temperature, liquid loading, allowable pressure drop, required outlet concentration, and the vessel dimensions the element must fit inside. If any of those is missing or quoted at a single duty point with no range, the sheet cannot be checked and should not be used to place an order.
Most datasheets in circulation look complete because they are long. They list mesh density, wire diameter, material, bed thickness, gasket type, and surface finish — all of which are outputs of the sizing, not inputs to it. Reading them in the wrong order is how plants end up with elements that meet the drawing and fail the duty.
Two suppliers can quote the same duty and differ by 40 per cent without either being wrong; the five conventions responsible are set out in why the same demister duty gives different diameters.
Read it in this order
| # | Parameter | Why it matters | Red flag if missing |
|---|---|---|---|
| 1 | Vapor mass flow, min / normal / max | Sets velocity and therefore efficiency and flooding margin | Only one flow quoted |
| 2 | Operating pressure and temperature | Determines vapor density; a hot light gas at the same mass flow is far above design velocity | Standard conditions quoted instead of operating |
| 3 | Liquid loading | Drives drainage sizing and the choice of mesh density | Liquid rate absent or described only as “wet gas” |
| 4 | Allowable pressure drop | Caps how thick or dense the element can be; sets the fan duty | “As low as possible” |
| 5 | Required outlet concentration | Defines the duty in a measurable way | Only “high efficiency” claimed |
| 6 | Vessel ID, orientation, connection size | Determines geometry, and whether the pad can physically be installed | Drawing referenced but not supplied |
The parameters that are output, not input
Once the six above are fixed, the rest follow deterministically:
- Face area and diameter — from flow and design velocity
- Mesh density — from required efficiency and fouling risk. Higher density improves fine droplet capture and worsens fouling
- Bed thickness — from required efficiency at the design velocity. Efficiency rises with thickness but so does pressure drop, roughly linearly
- Material grade — from corrosivity and temperature, not from preference
- Drainage arrangement — from liquid loading and orientation
If a supplier quotes mesh density and thickness without showing the velocity calculation, you are looking at a catalogue selection rather than an engineered one. That is acceptable for a like-for-like replacement of a known-good element and unacceptable for a new duty.
Five questions to ask about any datasheet
- At what velocity is this element operating? If the sheet does not show design velocity, efficiency claims are unverifiable.
- What is the flooding margin? Design velocity should be 60–75% of the Souders-Brown maximum. If it is 90%, the element has no upset tolerance.
- Is the outlet concentration guaranteed or estimated? Only a guaranteed figure can be held against a compliance limit.
- What is the fouling assumption? An element sized for clean gas will plug in dirty service. The sheet should state whether washing is assumed.
- What is the pressure drop at the maximum case, not the normal case? Maximum case pressure drop is what the fan has to deliver.
A datasheet that can actually be checked
A usable sheet states operating conditions for at least three cases (minimum, normal, maximum), shows the calculated velocity for each, states the flooding margin, states the pressure drop for each case, and states the outlet concentration with the calculation basis. Geometry, material and thickness then follow from those numbers.
If you are replacing an existing element and have no original datasheet, the practical route is to measure the installed geometry and back-calculate — see our technical data sheet and cross-reference replacement guide, or send the measured data for a sizing review.
Frequently Asked Questions
What are the most important parameters on a mist eliminator datasheet?
The six that decide whether the element works are maximum vapor flow, operating pressure and temperature, liquid loading, allowable pressure drop, and required outlet concentration. Everything else on the sheet — material, thickness, mesh density, geometry — is derived from those six plus the vessel dimensions.
Why does the datasheet quote minimum and maximum flow?
The minimum flow sets the turndown limit below which velocity is too low for the pad to capture fine droplets effectively, or for drainage to work properly. The maximum flow sets the flooding limit. An element quoted only at a single duty point gives you no information about the range over which it will actually perform.
What does outlet concentration mean in practice?
It is the entrained liquid remaining in the gas downstream of the element, usually expressed in mg/Nm³ or ppm by mass. It is the number that determines whether downstream equipment, analyzers, or emission limits are satisfied, and it is the only number that matters if the element is installed for compliance rather than general cleanup.
- Gas-Liquid Separation Fundamentals — terminology, separation mechanisms and internal selection
- Technical Data Sheet — material and performance reference data
- All Technical Articles — complete engineering index
If you are working on a replacement
Most of the work behind an article like this is a replacement inside an existing vessel, where the available dimensions decide more than the nominal duty. See the process data needed to size and select it, the scope from data review through to delivery and what has to be supplied before a price is issued.
More on wire mesh demisters and demister pads
- How Does a Wire Mesh Demister Work? A Complete Guide – the guide that covers this device family end to end
- Demister Sizing: Why Western and Chinese Conventions Give Different Diameters
- Reboiler Mist Eliminators in Ethylene, C3 Splitter Heat Pumps and Refrigeration Chillers
- Why a Shorter Kettle Bundle Can Need a Larger Shell: Length, Diameter and Which Area Binds
- Entrainment Prediction in Kettle Reboilers, Why the Element Is Not Free to Size, and What CFD Is Actually For
Not sure which technology fits the duty at all? Which Mist Eliminator or Coalescer Do You Need? A Selection Map by Duty compares all four on droplet cut point, pressure drop and fouling tolerance.